Our read & the right size
At 2.33 kWh/day, the Beverage-Air HRP1WHC***G******** runs in the less-efficient 91% of the 272 comparable 1-door reach-in refrigerators we track — about $62/yr over the median.
A single-door reach-in (~20 cu ft) fits a prep station, a small café, or a tight spot on the line. Choose it when one section holds a shift's product — step up to two doors before you're opening it constantly.
30.76 cu ft is roughly 1.5× a typical home refrigerator — about 15 full sheet pans or ~26 cases of product (varies with shelving).
Photos & drawings
Full specifications
| Type | Reach-in refrigerator, glass door |
| Doors | 1 |
| Total volume | 30.76 cu ft |
| Exterior (H × W × D) | 78.5 × 35 × 30 in |
| Energy consumption | 2.33 kWh/day |
| Refrigerant | R-290 (GWP 3) |
| Defrost | Automatic |
| Certification | ENERGY STAR certified |
| Origin | Made in USA (brand-level — verify on cut sheet) |
| On market since | 04/01/2019 |
Refrigerant & future-proofing FUTURE-PROOF
Uses R-290 (GWP 3) — a low-GWP natural refrigerant, well under regulatory thresholds and unaffected by the HFC phase-down.
Energy & cost of ownership
≈ $1,390 over a 10-year life at the US average commercial rate — adjust to your utility rate for a local figure.
Utility rebates ENERGY STAR
Because this model is ENERGY STAR certified, it is commonly eligible for commercial-kitchen utility rebates (many electric utilities pay $50–$400 per qualifying reach-in). Check your utility’s foodservice program. Find rebates in your area →
Cross-reference — comparable 1-door models
| Brand / model | Volume | Energy | vs. this |
|---|---|---|---|
| Turbo Air TJMR-30SD**-N-$ | 32.04 cu ft | 2.31 kWh/d | ↓ 1% less |
| Continental 1RXN | 28.66 cu ft | 1.58 kWh/d | ↓ 32% less |
| Imbera VR27 CZ HC | 27.8 cu ft | 2.45 kWh/d | ↑ 5% more |
| HABCO SE40eHC | 34.15 cu ft | 2.66 kWh/d | ↑ 14% more |
| True Refrigeration TG1R-1S-HC | 27.33 cu ft | 1.28 kWh/d | ↓ 45% less |
Matched on type, door count and capacity (±15%).
Health-department & code relevance NSF/ANSI 7
Commercial kitchens holding cold TCS foods need NSF-listed refrigeration that holds 41°F (5°C) or below (FDA Food Code 3-501.16). Equipment must be commercially certified for sanitation (4-205.10, NSF/ANSI 7). This model is ENERGY STAR certified; confirm the NSF mark on the cut sheet.
Frequently asked
What temperature does the Beverage-Air HRP1WHC***G******** hold?
How much does it cost to run?
Is R-290 refrigerant a problem?
Is it NSF certified?
Video
No product video on file yet. Search YouTube for Beverage-Air HRP1WHC***G******** ↗
Shipping & handling
UPS / small parcel — ships ground, no freight appointment or liftgate needed.
| Ships by | UPS / ground parcel |
| Product weight | See spec sheet |
| Shipping weight | See spec sheet |
| Shipping dimensions | See spec sheet |