Our read & the right size
At 8.84 kWh/day, the Victory FSA-2D*EW****HC runs in the less-efficient 73% of the 114 comparable 2-door reach-in freezers we track — about $96/yr over the median.
A two-door reach-in freezer (~43 cu ft) is the standard for a line that holds meaningful frozen inventory without a walk-in freezer. Watch energy use — freezers cost roughly double a fridge to run.
48.26 cu ft is roughly 2.4× a typical home refrigerator — about 24 full sheet pans or ~40 cases of product (varies with shelving).
Photos & drawings
Full specifications
| Type | Reach-in freezer, solid door |
| Doors | 2 |
| Total volume | 48.26 cu ft |
| Exterior (H × W × D) | 78.25 × 58.38 × 33.13 in |
| Energy consumption | 8.84 kWh/day |
| Refrigerant | R-290 (GWP 3) |
| Defrost | Automatic |
| Certification | ENERGY STAR certified |
| Origin | Made in USA (brand-level — verify on cut sheet) |
| On market since | 08/15/2019 |
Refrigerant & future-proofing FUTURE-PROOF
Uses R-290 (GWP 3) — a low-GWP natural refrigerant, well under regulatory thresholds and unaffected by the HFC phase-down.
Energy & cost of ownership
≈ $5,260 over a 10-year life at the US average commercial rate — adjust to your utility rate for a local figure.
Utility rebates ENERGY STAR
Because this model is ENERGY STAR certified, it is commonly eligible for commercial-kitchen utility rebates (many electric utilities pay $50–$400 per qualifying reach-in). Check your utility’s foodservice program. Find rebates in your area →
Cross-reference — comparable 2-door models
| Brand / model | Volume | Energy | vs. this |
|---|---|---|---|
| Novum 1300F TD | 48.5 cu ft | 11.13 kWh/d | ↑ 26% more |
| FRESH FRB-49FS-HC | 47.92 cu ft | 5.44 kWh/d | ↓ 38% less |
| Continental 2FEN | 48.64 cu ft | 9.45 kWh/d | ↑ 7% more |
| Traulsen RLT232NUT-FHS | 46.02 cu ft | 9.48 kWh/d | ↑ 7% more |
| Desmon Spa PBB14C-A | 45.79 cu ft | 8.31 kWh/d | ↓ 6% less |
Matched on type, door count and capacity (±15%).
Health-department & code relevance NSF/ANSI 7
Commercial kitchens holding cold TCS foods need NSF-listed refrigeration that holds 0°F (−18°C) or below (FDA Food Code 3-501.16). Equipment must be commercially certified for sanitation (4-205.10, NSF/ANSI 7). This model is ENERGY STAR certified; confirm the NSF mark on the cut sheet.
Frequently asked
What temperature does the Victory FSA-2D*EW****HC hold?
How much does it cost to run?
Is R-290 refrigerant a problem?
Is it NSF certified?
Video
No product video on file yet. Search YouTube for Victory FSA-2D*EW****HC ↗
Shipping & handling
UPS / small parcel — ships ground, no freight appointment or liftgate needed.
| Ships by | UPS / ground parcel |
| Product weight | See spec sheet |
| Shipping weight | See spec sheet |
| Shipping dimensions | See spec sheet |